Friday, February 28, 2014

Quality Indicators in the Preanalytical Phase of Testing in a Stat Laboratory

Study objective: To quantify performance in the preanalytical phase in a stat laboratory using quality indicators, and compare our results with those in the literature to improve laboratory services.

During the 1-year period, a total of 168,728 samples and 88655 requests forms were received in stat laboratory. The total number of preanalytical errors was 1457, accounting for 0.8% of the total number of samples received in a year. Of the total preanalytical errors, 46.4% were hemolysed samples (biochemistry), 43.2% were clotted samples (hematology), 6.4% were samples lost-not received in the laboratory, 2.9% samples showed an inadequate sample-anticoagulant ratio, 0.7% were requests with errors in patient identification, 0.3% were samples collected in blood collection tubes with inappropriate anticoagulant and 0.1% were requests with errors–missing test requests.

Read more:
Quality Indicators in the Preanalytical Phase of Testing in a Stat Laboratory

 Source: Lab Medicine